AN 1002: 전해질 틸트 센서 작동 사양의 정의

1 Description

The purpose of this application note is to define the terms used in the operating specifications of electrolytic tilt sensors.

Back to Table of Contents

2 Terms and Definitions

Term Definition
운영 범위 단조출력을 관찰할 수 있는 최대 범위입니다.
선형 범위 The maximum range over which the deviation of the output from a linear best fit is within a specified percentage value.
선형성 The maximum deviation from a linear output as a percentage of the measurement range.
반복성 The maximum deviation in output when the sensor is tilted and then returned to its original position.
해상도 The minimum incremental position change that generates a monotonic output.
대칭 The maximum deviation in output between two symmetrical positions on either side of null.
Null의 최대 전류 The maximum recommended current through the sensor at null at 23 °C which will not cause damage to the sensor.
널 임피던스 The impedance between the outer electrodes when the sensor is in the null position at 23 °C.
작동 온도 The temperature range over which typical output behavior is observed.
보관 온도 The temperature range that will not physically or chemically alter the sensor while it is not in use.
24-Hour Stability The maximum variation in sensor output over a 24-hour period while the sensor remains stationary at null.
Null 온도 계수 The maximum output change at null per degree of temperature change above or below 23 °C.
스케일 온도 계수 A coefficient to compensate for the change in gain caused by variations in temperature from 23 °C.
Null 오프셋 The maximum deviation between the electrical null of the sensor and the mechanical null where the sensor is parallel to the surface of the Earth.
Cross-Axis Error The maximum deviation of the output on one axis while tilting along the perpendicular axis.
시간 상수 The amount of time required for the sensor output to reach at least 63.2% of its final value.