The Fredericks Company Remains Open - Check for the latest COVID-19 updates Learn more

Fredericks Company
  • Cart
  • My Account

Contact us at
+1 215 947 2500

  • Products
    • Tilt Measurement
    • Selection Guide
    • Televac Vacuum Measurement
    • Selection Guide
    • MX200 Configurator
    • Calibration & Service
    • Precision Components
  • Markets
    • Tilt Markets
    • Agricultural Vehicles
    • Construction Tools, Laser Leveling
    • Construction Vehicles
    • Geotechnical Monitoring and Structural Monitoring
    • RV Leveling
    • Satellite Antenna Positioning
    • Televac Vacuum Markets
    • E-Beam Welding
    • Freeze Dryers
    • Liquefied Natural Gas (LNG), Industrial Gas, Cryogenics
    • Medical Particle Accelerators
    • National Labs, Research and Development
    • Semiconductor
    • Thin Film Deposition
    • Vacuum Distillation
    • Vacuum Furnace, Heat Treat
    • Vacuum Glove Boxes
  • About Us
    • About Us
    • ISO Certification
    • Ordering Info
    • Warranty Info
    • Terms and Conditions
    • Frequently Asked Questions
  • Resources
    • Frequently Asked Questions
    • Tilt Measurement Resources
    • Instruction Manuals
    • Datasheets
    • Application Notes
    • Televac Vacuum Resources
    • Instruction Manuals
    • Datasheets
    • Application Notes
    • MX200 Configurator
    • Calibration & Service
    • Vacuum Measurement Converter
    • #MeasureMemes
    • Blog
  • Contact Us
    • Contact Us
    • Request a Quote
    • Televac Calibration & Service
    • Technical Support
    • Find a Tilt Measurement Rep
    • Find a Televac Rep
1F Diaphragm
1 - 7600 Torr
1E Diaphragm
1 - 1000 Torr
4A Convection
10-3 - 1000 Torr
MX4A Convection
10-4 - 1000 Torr
2A Thermocouple
10-3 - 20 Torr
MX2A Thermocouple
10-4 - 1000 Torr
CC-10 Wide Range
10-9 - 1000 Torr
7B Cold Cathode
10-7 - 10-3 Torr
MX7B Cold Cathode
10-8 - 10-3 Torr
MX7M Cold Cathode
10-11 - 10-2 Torr
7E Cold Cathode
10-8 - 10-2 Torr
7F/7FC/7FCS Cold Cathode
10-11 - 10-2 Torr
3F Mini BA Hot Ion
10-10 - 10-2 Torr

Tilt Sensors
  • Overview
  • TrueTILT™ Wide Range
    • Overview
    • 0717-4313-99 (±50°)
    • 0717-4315-99 (±60°)
    • 0717-4318-99 (±60°)
    • 0717-4319-99 (±50°)
    • 0717-4321-99 (±40°)
    • 0717-4322-99 (±45°)
    • 0717-4323-99 (±50°)
  • TrueTILT™ Mid-Range
    • Overview
    • 0703-1602-99 (±25°)
  • TrueTILT™ Narrow Range
    • Overview
    • 0703-0711-99 (±3°)
  • Glass Wide Range
    • Overview
    • 0716-2201-99 (±70°)
    • 0716-5201-99 (±70°)
    • 0717-2201-99 (±70°)
    • 0717-5201-99 (±70°)
  • Glass Mid-Range
    • Overview
    • 0737-0101-99 (±10°)
    • Encapsulated 0719-3705-99 (±10°)
  • Glass Narrow Range
    • Overview
    • 0711-0763-99 (±1°)
    • 0711-0768-99 (±3°)
    • 0737-1203-99 (±0.5°)
    • Encapsulated 0719-1138-99 (±1°)
    • Encapsulated 0719-1143-99 (±3°)
    • Encapsulated 0719-3703-99 (±0.5°)
  • Micro-Arc Wide Range
    • Overview
    • 0728-1025-99
  • Legacy Tilt Products
    • Overview
    • 0737-0604-99
    • Encapsulated 0719-3701-99
    • 0703-0703-99
    • 0717-4304-99
Tilt Sensor Assemblies
  • Overview
  • Signal Conditioners - Electrolytic Tilt Sensor Circuits
    • Overview
    • 1-6200-005 (SPI)
    • 1-6200-006 (RS-232)
    • 1-6200-007 (An/PWM)
    • 1-6200-008 (RS-485)
    • 1-6200-012 (An/RS-232)
  • Inclinometer Sensors
    • Overview
    • ApexOne
    • 0729-1751-99
    • 0729-1752-99
    • 0729-1753-99
    • 0729-1765-99
    • 0729-1754-99
    • 0729-1755-99
    • 0729-1759-99
    • 0729-1760-99
    • 0729-1760-04
    • MEMS Sensors - Inclinometers
      • Overview
      • 0751-3002-99 (±30°)
      • 0751-9002-99 (±90°)
      • 0750-3002-99 (±30°)
      • 0750-9002-99 (±90°)
  • Tilt Switches
    • Overview
    • 0729-1763-XX (±45°)
    • 0729-1736-99 (±35°)
    • 0729-1757-99 (±45°)
    • 0729-1758-99 (±45°)
Technical Information
  • Technical Information
  • Application Notes
    • AN 1000: Electrolytic Tilt Sensor Excitation
    • AN 1001: Temperature Compensation of Electrolytic Tilt Sensors
    • AN 1002: Definitions of Electrolytic Tilt Sensor Operating Specifications
    • AN 1003: Configuring Tera Term for Use with TFC Tilt Products
    • AN 1004: Inclinometers for Solar Tracking Systems
    • AN 1005: Converting Tilt Angle to Degrees
    • AN 1006: Obtaining Measurements from TFC Signal Conditioners
  • Datasheets
  • Manuals
  • Sample Applications
Product Lines
  • Tilt Measurement
  • Televac Vacuum Measurement
  • Precision Components

Product Selection Guide
Contact Us

Contact Us Today

Glass Wide Range Electrolytic Tilt Sensors

Glass Wide Range

Electrolytic Tilt Sensors

These electrolytic tilt sensors are designed to give wide range measurement up to ±70° with very high accuracy of at least ±0.003° in one axis. These sensors are more expensive than any of our TrueTILT™ metal solutions because of the higher accuracy of the glass sensor and the glass design.

All electrolytic tilt sensors require electrolytic tilt sensor circuit (commonly referred to as signal conditioning or signal conditioners) to provide a tilt output. This electrolytic tilt sensor circuit can be built into your system or you can purchase circuitry that we’ve designed that’s optimized for the best performance from our sensors.

To learn more about the principles of electrolytic tilt sensors and how to integrate sensors into your application, see our Technical Information page.
0716-2201-99 (±70°)
Operating Range: ± 70°
Repeatability: ±0.003°
0716-5201-99 (±70°)
Operating Range: ± 70°
Repeatability: ±0.003°
electrolytic tilt sensor
0717-2201-99 (±70°)
Operating Range: ± 70°
Repeatability: ±0.003°
0717-5201-99 (±70°)
Operating Range: ± 70°
Repeatability: ±0.003°

Social Media

Contact

The Fredericks Company
2400 Philmont Avenue
Huntingdon Valley, PA 19006

+1 215 947 2500
[email protected]

Products

  • Tilt Measurement
  • Televac Vacuum Measurement
  • Precision Components

Navigation

  • Homepage
  • About Us
  • ISO Certification
  • Blog
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • Site Map