The TELEVAC MP7FR Active Gauge utilizes an easily replaceable TELEVAC 7F double inverted magnetron cold cathode vacuum sensor. It has a variety of features including a wide range of measurement from 1×10-11 Torr to 1×10-2 Torr, a programmable set point, a factory settable analog output, and an LED display. This unit indirectly measures absolute pressure by ionizing gas in the presence of a magnetic field. Unlike hot ion sensors, this unit is resistant to inrushes of gas. The design allows for easy disassembly for replacement of the sensor.

The TELEVAC MP7FR Features

  • Compact design
  • Mountable in any orientation
  • Minimal stray magnetic field
  • Superior unit-to-unit performance
  • Excellent customer support
  • Designed and manufactured in the United States of America
Operating Range 1×10-11 Torr to 1×10-2 Torr
Communications N/A
Analog Output 0 V to 10 V DC
Programmable Set Points 1
Set Point Type Relay
Supply Voltage 24 V DC
Maximum Power 6 W
Calibration Medium Dry air or nitrogen
Overpressure 150 psi
Digital Output Resolution 2 significant digits with exponent
Operating Temperature 0 °C to 50 °C
Storage Temperature -20 °C to 60 °C
Bakeout Temperature 150 °C (electronics removed)
400 °C (electronics and magnets removed)
Display Readable Distance 3 m (10 ft)
Accuracy
1×10-7 Torr to 1×10-2 Torr ±0.2 decade
Analog Output ±5 mV


Output X1 Logarithmic, 3 Logarithmic
MP7FR with 2.75” CF (DN40 ISO-CF-F) Stainless Steel2-7970-X52

MX4A Active Gauge – The MX4A utilizes an easily replaceable TELEVAC 4A convection vacuum sensor. It has a variety of features including a wide range of measurement from 1 × 10-4 Torr up to 1000 Torr, RS-485 communications, two programmable set points, and a selectable analog output. The bright OLED display makes it easy to read from a distance. Options can be set from four capacitive touch controls located on the top of the unit or through RS-485 communications. The extensive selection of fittings, simplicity of use, ease of sensor replacement, and competitive cost make this unit an excellent choice for a variety of vacuum applications.

MP7ER Active Gauge – This gauge measures high vacuum from 1 × 10-8 Torr to 1 × 10-2 Torr utilizing a cleanable double inverted magnetron sensor. It has a linear or logarithmic 0 V to 10 V analog output with a relay set point and an LED display of pressure.



Freeze drying and food packaging
Cryogenics
Load-lock
Semiconductor
Heat treating and vacuum furnaces
Thin film deposition and coating processes
Pharmaceutical product processes